Atmospheric Plasma Jet-Flow system (Plasma Pen) for Surface Treatment-GSL1100XPJF

Product image 1

Atmospheric Plasma Jet-Flow system (Plasma Pen) for Surface Treatment-GSL1100XPJF

GSL1100X-PJF is a compact Atmospheric Plasma Jet-Flow ( so-called  Plasma Beam, Plasma Pen) system for surface Treatment, which consists of RF generator, flexible gas delivery pipe, and plasma beam head. The plasma jet flow can activate and clean material surface rapidly at low temperature without vacuum, such as single crystal wafer, optical component, plastics, etc. It is an excellent tool for cleaning wafer surfaces before epitaxial or optical fiber before welding to obtain higher quality. This device also may be used for studying atmosphere pressure CVD.

SPECIFICATIONS:
Features
  • High-speed surface treatment with a simple and safe operation
  • Neither vacuum  nor chamber required with versatile plasma chemistry
  • Handheld or in-line processing at low cost
  • lightweight and compact size
Input Power
  • Standard AC 208V - 240V, 50/60 Hz,
  • 1000W
  • AC110V power is available with an additional 1000W transformer, please order separately
Output Frequency
  • 20-23 kHz
Plasma Beam

  • one plasma beam head is included
  • Beam head size10-12mm diameter.
  • Temperature:         Beam temperature is < 60oC for short time.  The plasma beam shall keep scanning to keep the sample surface temperature low.

Input Gas Pressure and Working Gases

  • 40 PSI min.
  • Air, N2, Ar, He, or any mixed gas  ( 5N purity prefered0
  • Dry compressive gas can be used
  • ( no flammable and explosive gases)
Plasma working Pressure 7- 10 PSI

Working Environment
  • Temperature: < 42°C
  • Humidity:: : ≤ 40RH
  •  No flammable gas
Overall Dimensions 380 (W) ×210 (H) ×500 (D) mm
Net Weight 10 kg

Warranty & Certificate
  • One year limited with lifetime support
  • CE certified
Operation Manual

     
Application Notes

  • This Atmospheric Plasma Jet-Flow system is excellent to clean plastic, polymer, and oxide substrate surface before coating
  • You may click the picture below to order our automatic scan system to achieve clean or coating for a 10" x 10" area
$5,595.10

Original: $15,986.00

-65%
Atmospheric Plasma Jet-Flow system (Plasma Pen) for Surface Treatment-GSL1100XPJF

$15,986.00

$5,595.10

Product Information

Shipping & Returns

Description

GSL1100X-PJF is a compact Atmospheric Plasma Jet-Flow ( so-called  Plasma Beam, Plasma Pen) system for surface Treatment, which consists of RF generator, flexible gas delivery pipe, and plasma beam head. The plasma jet flow can activate and clean material surface rapidly at low temperature without vacuum, such as single crystal wafer, optical component, plastics, etc. It is an excellent tool for cleaning wafer surfaces before epitaxial or optical fiber before welding to obtain higher quality. This device also may be used for studying atmosphere pressure CVD.

SPECIFICATIONS:
Features
  • High-speed surface treatment with a simple and safe operation
  • Neither vacuum  nor chamber required with versatile plasma chemistry
  • Handheld or in-line processing at low cost
  • lightweight and compact size
Input Power
  • Standard AC 208V - 240V, 50/60 Hz,
  • 1000W
  • AC110V power is available with an additional 1000W transformer, please order separately
Output Frequency
  • 20-23 kHz
Plasma Beam

  • one plasma beam head is included
  • Beam head size10-12mm diameter.
  • Temperature:         Beam temperature is < 60oC for short time.  The plasma beam shall keep scanning to keep the sample surface temperature low.

Input Gas Pressure and Working Gases

  • 40 PSI min.
  • Air, N2, Ar, He, or any mixed gas  ( 5N purity prefered0
  • Dry compressive gas can be used
  • ( no flammable and explosive gases)
Plasma working Pressure 7- 10 PSI

Working Environment
  • Temperature: < 42°C
  • Humidity:: : ≤ 40RH
  •  No flammable gas
Overall Dimensions 380 (W) ×210 (H) ×500 (D) mm
Net Weight 10 kg

Warranty & Certificate
  • One year limited with lifetime support
  • CE certified
Operation Manual

     
Application Notes

  • This Atmospheric Plasma Jet-Flow system is excellent to clean plastic, polymer, and oxide substrate surface before coating
  • You may click the picture below to order our automatic scan system to achieve clean or coating for a 10" x 10" area

You may also like

-65%
Thumbnail 1

0.7 L Plasma Cleaner with Digital Vacuum Gauge, 3"Dx 6.5"L Quartz Chamber, 13.56 Mhz - PCE3

$9,998.00

$3,499.30

Thumbnail 1Thumbnail 2

NRTL Certified 30L Heated Ultrasonic Cleaner w/ Digital Timer (500×300×200 mm) - SK8300BT

$4,998.00

-65%
Thumbnail 1

8.5" RF Plasma Cleaner / Etcher with Vacuum Pump. (12 Liter, 13.56 Mhz, 80W max.) - EQ-PCE-8

$29,985.00

$10,494.75

-65%
Thumbnail 1Thumbnail 2

Desktop UV-Ozone Cleaner with 12" x 12" Chamber and Heating Stage up to 150C - PCE22

$9,998.00

$3,499.30

-65%
Thumbnail 1Thumbnail 2

Corona (Air Plasma) Surface Treatment System ( 20 or 30 cm width) for Substrate Cleaning by Roll to Roll - MSK-EC-200

$7,869.00

$2,754.15

Thumbnail 1Thumbnail 2

150 Heat-able UV-Ozone Cleaner w/ 6"x 6" Chamber & Quartz Holder- PCE66H

$4,996.00

-65%
Thumbnail 1Thumbnail 2

Compact UV-Ozone Cleaner with Stirring Function and Heating for Powder Cleaning - PCE-66MX

$5,598.00

$1,959.30

-65%
Thumbnail 1

Atmospheric Plasma Beam with Automatic Scanning System for Surface Treatment- GSL1100X-PJF-A

$28,989.00

$10,146.15

-65%
Thumbnail 1Thumbnail 2

3 L Plasma Cleaner with Vacuum Pump & Digital Controller, 6"Dx6.5"L Quartz Chamber - PCE6

$13,998.00

$4,899.30

Thumbnail 1Thumbnail 2

Atmospheric Plasma Beam with Automatic Scanning System and Heating Plate for Surface Treatment- GSL1100X-PJF-H

$36,898.00

-65%
Thumbnail 1Thumbnail 2

NRTL Certified 5L Heated Ultrasonic Cleaner w/ Digital Timer280x140x150 mm) - VGT1860QTD

$759.00

$265.65